1. Layers short circuit testing composition:
(1). Testing waveform: 1.2x40Μs
(2). Testing voltage: 100~1500Vp.p. Operate through manual setup on setup panel. Present in digital form , accuracy: ±5% Of F.S.
(3).Identify: After reading the inrush current value by PLC, making OK/NG judgment with the benchmark. And record the test value.
(4).Testing frequency: 4 times on 90 degree; 1 time on 180 degree.
2. Hipot Test:
(1).Testing Method: between commutator and shaft.
(2). Testing Voltage: AC100~1500V. Adjust voltage manually and analog voltage meter. Accuracy: ±5% Of F.S.
(3). Leakage current Setting: 0.5/1/2/5/10mA , 5 section setting. Accuracy: ±1% Of F.S.
(4). Automatic circuit inspection: Operate through manual setup on setup panel. When circuit leakage reaches to max. per setup, alarm automatically. PLC reads signal.
3. DC Resistance Test:
(1). Testing Method: DC constant current is applied to the coil under test and adopt the four-terminal method for detection.
(2). Testing Range: 10~1000.0mΩ, 1~10Ω with 20°C automatic temperature compensation.
(3). Accuracy: ±0.5% of F.S.
(4). Result judgment: The test value is read by the PLC and it is automatically compared with upper and lower limit values stored in the internal storage.
(5). Testing frequency: commutator